Keco Drive vs a VFD
and motor for peristaltic pumps.
A conventional setup pairs a motor, a variable frequency drive (VFD) and a separate operator interface. Keco Drive is not a VFD. It is a digital-controlled hybrid motor: a permanent-magnet motor, drive electronics and 7‑inch touchscreen built as one unit for Ragazzini Rotho S5, S10, S16, S26 and M34 pumps. It is pre-launch, so keep your VFD if you need a drive today.
What does a VFD and motor stack involve?
A VFD varies the frequency and voltage fed to an AC motor to change its speed. On a peristaltic pump, a working installation is usually several separately specified parts:
- An AC induction motor, often inverter-duty, sized for the pump's torque across its speed range
- A gear reducer when the pump needs shaft speeds lower than the motor can hold continuously
- The VFD, programmed with motor nameplate data, speed limits, ramps and I/O scaling
- An enclosure or panel for the drive, plus the wiring between them
- An operator interface: the drive keypad, a separate HMI or PLC screens
- Dosing logic for volume or batch runs, usually written in a PLC by an integrator
VFDs are mature, widely stocked and work with most AC motors. The cost is coordination: several vendors, several manuals and an integrator to tie them together.
Low-speed metering adds a constraint: a fan-cooled induction motor loses cooling airflow as it slows, so long low-speed runs usually call for gear reduction, an inverter-duty rating or separate cooling.
What does Keco Drive put in one unit?
Keco Drive combines a permanent-magnet brushless synchronous servo motor (IE5+), a factory pre-wired control module and a 7-inch touchscreen. Each unit is designed to be matched and pre-programmed for your pump model, and setup is in software, with no jumpers, DIP switches or trim-pots.
Motor + controller NEMA 4X
7‑inch HMI Glove-ready
- VFD stackSeparate partsMotor · gear reducer · VFD · panel · HMI · PLC logic
- Keco DriveOne unitMotor · drive · 7‑inch HMI · eight dosing modes
Stack vs one unit No panel
The dosing logic an integrator would otherwise write is in the firmware: eight modes (Velocity, Duration, Volume, Flow Pacing, Analog Input, Frequency Input, Pulse and Calendar), drawdown-test calibration, auto and manual prime, and adaptive hose-life estimation with an alert.
Protection is built in: a hose-leak input, an auxiliary safety input, flow and low-flow confirmation inputs, and reversible flow with a safety confirmation. One HMI runs up to five Rotho pumps, each with its own speed, mode and hose-life counter.
Full spec sheet: every published figure, I/O signal type and operating mode
Keco Drive vs a VFD stack
Keco Drive figures are published Gen 1 Rev A specs. The VFD column describes a typical stack, which varies by plant.
| Item | Keco Drive Gen 1 | Typical VFD stack |
|---|---|---|
| What you install | One unit on the pump: motor, power and control module, 7-inch HMI | Motor, VFD, drive enclosure or panel, operator interface, often a gear reducer |
| Motor | Permanent-magnet brushless synchronous servo · IE5(+) · Class H(+) insulation | Usually an AC induction motor |
| Speed range | 0.001 to 100 RPM programmable · 100,000:1 turndown (Rotho S-Series) | Set by the motor, drive, gearing and cooling chosen |
| Operator interface | 7‑inch glove-compatible touchscreen · on the pump or remote (VESA 75 × 75) · browser access on the local network | Drive keypad, separate HMI or PLC screens |
| Dosing logic | Eight built-in modes, including Volume, Pulse and Calendar · units in mL, L or gallons | Programmed in a PLC or controller |
| Pump functions | Drawdown calibration · hose-leak input · hose-life alert · auto restart | Added by the integrator if required |
| Fieldbus | PROFINET · EtherNet/IP · Modbus TCP | Varies by drive model and option card |
| Enclosure | NEMA 4X / IP66 · indoor and outdoor · GRP control module, IK08 | Varies by drive and panel |
| Power | 100–240 VAC, single or three phase, GFCI compatible · KD-S 1 HP at 120 V · KD-M 2.5 HP at 230 V 3-phase | Matched to the motor and supply |
| Pumps it fits | Ragazzini Rotho S5, S10, S16, S26 (KD-S) and M34 (KD-M) | Almost any motor-driven pump |
Keep your VFD, or join early access?
Keco Drive is in final development. If you need a drive now, that settles it. Otherwise it comes down to the pump and the duty.
AKeep your VFD ifToday
- You need a drive installed now. Keco Drive is pre-launch.
- Your pump is not a Rotho S5, S10, S16, S26 or M34, the Gen 1 compatible models.
- The duty needs more than the KD-M's 2.5 HP continuous rating.
- Your plant standardizes on one drive platform and it already meets your turndown.
BJoin early access ifPlanning
- You meter with Rotho S-Series pumps and need 0.001 to 100 RPM.
- You are planning a new skid that would otherwise need a drive panel, HMI and integration.
- You want several pumps on one screen with volume or pulse dosing and no PLC programming.
- You want hose-failure detection and hose-life alerts at the pump.
Pre-launch: Gen 1 Rev A figures. Specifications may change before production.
Keco Drive vs VFD
questions.
Is the Keco Drive a VFD?
No. A VFD is a separate box that changes the frequency fed to a motor. Keco Drive is a digital-controlled hybrid motor: the permanent-magnet motor, drive electronics and 7-inch touchscreen are built as one unit on the pump, so there is no drive to size, mount or program on its own.
Do I still need a separate HMI or drive panel?
No. The 7-inch glove-compatible touchscreen is part of the unit and mounts on the pump or remotely on a standard VESA 75 × 75 mount. Any web browser on the local network can monitor it with no proprietary software, and the enclosure is rated NEMA 4X / IP66 for indoor and outdoor use.
What replaces the dosing logic I'd program in a PLC?
The drive's firmware. Eight modes are built in: Velocity, Duration, Volume, Flow Pacing, Analog Input, Frequency Input, Pulse and Calendar. Volume is set in mL, L or gallons and time in seconds, minutes, hours or days, and flow is calibrated with a drawdown test entered on the drive. Your PLC can still send the analog, frequency or pulse signal.
What pump protection does a VFD stack leave to the integrator?
Hose and flow protection. On a VFD stack, those inputs are wired and programmed by the integrator if required. Keco Drive has a leak-detector input for hose failure, an auxiliary safety input, flow and low-flow confirmation inputs with an alert, and reversible flow with a safety confirmation.
Replacing a VFD stack on Rotho pumps?
Join the early-access list to get the brochure by email. Founding members get first allocation when production opens.