A conventional setup pairs a motor, a variable frequency drive (VFD) and a separate operator interface. Keco Drive is not a VFD. It is a digital-controlled hybrid motor: a permanent-magnet motor, drive electronics and 7‑inch touchscreen built as one unit for Ragazzini Rotho S5, S10, S16, S26 and M34 pumps. It is pre-launch, so keep your VFD if you need a drive today.

01 · The conventional stack

What does a VFD and motor stack involve?

A VFD varies the frequency and voltage fed to an AC motor to change its speed. On a peristaltic pump, a working installation is usually several separately specified parts:

  • An AC induction motor, often inverter-duty, sized for the pump's torque across its speed range
  • A gear reducer when the pump needs shaft speeds lower than the motor can hold continuously
  • The VFD, programmed with motor nameplate data, speed limits, ramps and I/O scaling
  • An enclosure or panel for the drive, plus the wiring between them
  • An operator interface: the drive keypad, a separate HMI or PLC screens
  • Dosing logic for volume or batch runs, usually written in a PLC by an integrator

VFDs are mature, widely stocked and work with most AC motors. The cost is coordination: several vendors, several manuals and an integrator to tie them together.

Low-speed metering adds a constraint: a fan-cooled induction motor loses cooling airflow as it slows, so long low-speed runs usually call for gear reduction, an inverter-duty rating or separate cooling.

02 · One unit

What does Keco Drive put in one unit?

Keco Drive combines a permanent-magnet brushless synchronous servo motor (IE5+), a factory pre-wired control module and a 7-inch touchscreen. Each unit is designed to be matched and pre-programmed for your pump model, and setup is in software, with no jumpers, DIP switches or trim-pots.

01 Keco Drive motor and controller mounted on a Ragazzini Rotho peristaltic pump

Motor + controller NEMA 4X

02 Keco Drive 7-inch touchscreen HMI showing the Velocity screen

7‑inch HMI Glove-ready

03
  • VFD stackSeparate partsMotor · gear reducer · VFD · panel · HMI · PLC logic
  • Keco DriveOne unitMotor · drive · 7‑inch HMI · eight dosing modes

Stack vs one unit No panel

The dosing logic an integrator would otherwise write is in the firmware: eight modes (Velocity, Duration, Volume, Flow Pacing, Analog Input, Frequency Input, Pulse and Calendar), drawdown-test calibration, auto and manual prime, and adaptive hose-life estimation with an alert.

Protection is built in: a hose-leak input, an auxiliary safety input, flow and low-flow confirmation inputs, and reversible flow with a safety confirmation. One HMI runs up to five Rotho pumps, each with its own speed, mode and hose-life counter.

Full spec sheet: every published figure, I/O signal type and operating mode

03 · Side by side

Keco Drive vs a VFD stack

Keco Drive figures are published Gen 1 Rev A specs. The VFD column describes a typical stack, which varies by plant.

Keco Drive Gen 1 compared with a typical VFD and motor stack
ItemKeco Drive Gen 1Typical VFD stack
What you installOne unit on the pump: motor, power and control module, 7-inch HMIMotor, VFD, drive enclosure or panel, operator interface, often a gear reducer
MotorPermanent-magnet brushless synchronous servo · IE5(+) · Class H(+) insulationUsually an AC induction motor
Speed range0.001 to 100 RPM programmable · 100,000:1 turndown (Rotho S-Series)Set by the motor, drive, gearing and cooling chosen
Operator interface7‑inch glove-compatible touchscreen · on the pump or remote (VESA 75 × 75) · browser access on the local networkDrive keypad, separate HMI or PLC screens
Dosing logicEight built-in modes, including Volume, Pulse and Calendar · units in mL, L or gallonsProgrammed in a PLC or controller
Pump functionsDrawdown calibration · hose-leak input · hose-life alert · auto restartAdded by the integrator if required
FieldbusPROFINET · EtherNet/IP · Modbus TCPVaries by drive model and option card
EnclosureNEMA 4X / IP66 · indoor and outdoor · GRP control module, IK08Varies by drive and panel
Power100–240 VAC, single or three phase, GFCI compatible · KD-S 1 HP at 120 V · KD-M 2.5 HP at 230 V 3-phaseMatched to the motor and supply
Pumps it fitsRagazzini Rotho S5, S10, S16, S26 (KD-S) and M34 (KD-M)Almost any motor-driven pump
04 · Fit

Keep your VFD, or join early access?

Keco Drive is in final development. If you need a drive now, that settles it. Otherwise it comes down to the pump and the duty.

AKeep your VFD ifToday

  • You need a drive installed now. Keco Drive is pre-launch.
  • Your pump is not a Rotho S5, S10, S16, S26 or M34, the Gen 1 compatible models.
  • The duty needs more than the KD-M's 2.5 HP continuous rating.
  • Your plant standardizes on one drive platform and it already meets your turndown.

BJoin early access ifPlanning

  • You meter with Rotho S-Series pumps and need 0.001 to 100 RPM.
  • You are planning a new skid that would otherwise need a drive panel, HMI and integration.
  • You want several pumps on one screen with volume or pulse dosing and no PLC programming.
  • You want hose-failure detection and hose-life alerts at the pump.

Pre-launch: Gen 1 Rev A figures. Specifications may change before production.

05 · Questions

Keco Drive vs VFD
questions.

Is the Keco Drive a VFD?

No. A VFD is a separate box that changes the frequency fed to a motor. Keco Drive is a digital-controlled hybrid motor: the permanent-magnet motor, drive electronics and 7-inch touchscreen are built as one unit on the pump, so there is no drive to size, mount or program on its own.

Do I still need a separate HMI or drive panel?

No. The 7-inch glove-compatible touchscreen is part of the unit and mounts on the pump or remotely on a standard VESA 75 × 75 mount. Any web browser on the local network can monitor it with no proprietary software, and the enclosure is rated NEMA 4X / IP66 for indoor and outdoor use.

What replaces the dosing logic I'd program in a PLC?

The drive's firmware. Eight modes are built in: Velocity, Duration, Volume, Flow Pacing, Analog Input, Frequency Input, Pulse and Calendar. Volume is set in mL, L or gallons and time in seconds, minutes, hours or days, and flow is calibrated with a drawdown test entered on the drive. Your PLC can still send the analog, frequency or pulse signal.

What pump protection does a VFD stack leave to the integrator?

Hose and flow protection. On a VFD stack, those inputs are wired and programmed by the integrator if required. Keco Drive has a leak-detector input for hose failure, an auxiliary safety input, flow and low-flow confirmation inputs with an alert, and reversible flow with a safety confirmation.

Early access · Founding program

Replacing a VFD stack on Rotho pumps?

Join the early-access list to get the brochure by email. Founding members get first allocation when production opens.

  • KECO Pump & Equipment · San Diego · since 1954
  • Built for Ragazzini Rotho S5, S10, S16, S26 & M34