Specifications · Gen 1 · Rev A

Keco Drive
specifications.

Keco Drive is a permanent-magnet motor, digital controller and 7‑inch touchscreen in one unit that mounts on a positive displacement pump. Gen 1 fits Ragazzini Rotho S5, S10, S16, S26 and M34 pumps and runs 0.001 to 100 RPM (100,000:1 turndown) on the S-Series. Every published figure is below. Comparing it with a drive you run today? Read Keco Drive vs a VFD and motor.

Speed range · S-Series
0.001 → 100 RPM
Display
7″ HMI
Operating modes
8
Enclosure
NEMA 4X · IP66
01 · General

General specifications

Keco Drive Gen 1 general specifications
ParameterSpecification
Speed & direction
Speed range0.001 to 100 RPM, programmable (Rotho S-Series)
Turndown100,000:1 (Rotho S-Series)
DirectionReversible, CW and CCW, with safety confirmation
Motor
TypePermanent-magnet (PM)
Efficiency classIE5(+)
InsulationClass H(+)
Standard output (KD-S)1 HP continuous at 120 V · 1.2 HP peak
High-torque output (KD-M)2.5 HP continuous at 230 V, 3-phase · 7.5 HP peak
Frame sizesNEMA 56C, NEMA 140TC, IEC D100
Motor operating temperature−40 to 158 °F (−40 to 70 °C)
Power
Main power100–240 VAC, single or three phase · GFCI compatible
Control power24 VDC
Display (HMI)
Screen7-inch (178 mm) capacitive glass touchscreen · TFT color · backlit LED
GlovesGlove-compatible
HousingAnodized aluminum
MountingOn the pump or remote · standard VESA 75 × 75
Display/HMI operating temperature−4 to 140 °F (−20 to 60 °C)
Remote accessAny web browser on the local network · no proprietary software
Enclosure
RatingNEMA 4X / IP66 · indoor and outdoor
Control module housingNon-metallic GRP · IK08 impact rating
Power & control module
IntegrationMounted on the motor and pre-wired at the factory
WiringM8 / M12 connectors and/or terminal block
Power supplyReplaceable 24 VDC supply with over-voltage and over-current protection
RelaysReplaceable, socket-mounted output relays
I/O controllerReplaceable, with LED status lights
Output protectionOver-current protection and inductive clamping on all outputs
Memory & clockNon-volatile memory · real-time clock with battery backup
ConfigurationIn software · no jumpers, DIP switches or trim-pots
Communication
FieldbusPROFINET · EtherNet/IP · Modbus TCP
Compatible pumps (Gen 1)
KD-SRagazzini Rotho S5, S10, S16, S26
KD-MRagazzini Rotho M34
02 · Inputs & outputs

Which inputs and outputs does Keco Drive have?

Each channel's signal type is set in software. Types marked * have limitations listed in the user manual.

Keco Drive input and output channels
QtyChannelSignal types
Inputs
1UniversalAnalog 0–5 V, 0–10 V, 0–20 mA*, 4–20 mA* · dry contact · NPN or PNP*
2DigitalDry contact · NPN or PNP*
1Analog0–5 V, 0–10 V, 0–20 mA*, 4–20 mA*
1Pulse / frequencyDry contact · NPN or PNP* · 24 V · 0–1000 Hz
Outputs
1Analog0–5 V*, 0–10 V*, 0–20 mA, 4–20 mA
1DigitalSinking · 9 W at 24 V max · 3.3–24 VDC logic compatible*
3RelayForm C · 240 V AC/DC
1Frequency24 V · 0–1000 Hz
03 · Operating modes

What are the eight operating modes?

Volume in mL, L or gallons. Time in seconds, minutes, hours or days.

Keco Drive operating modes
ModeHow it dosesSet by
VelocityContinuous dosing at a set speed or flow rateTouchscreen
DurationTime-based dosing: runs for a set timeTouchscreen
VolumeVolume-based dosing: delivers a set volumeTouchscreen
Flow PacingDosing follows an external signalExternal signal
Analog InputDosing follows an analog signal4–20 mA (0–20 mA) or 0–10 V
Frequency InputDosing follows a frequency signal0–1000 Hz, 24 V max
PulseA set volume or run time, started by input pulse(s)Digital or dry-contact pulse
CalendarA set volume or run time, started on a scheduleReal-time clock
04 · Built-in functions

Which functions are built in?

AHose & safetyMonitoring

  • Leak detector input for hose failure
  • Auxiliary safety input
  • Adaptive hose-life estimation with alert
  • Flow and low-flow confirmation inputs with alert
  • Auto restart after a power interruption
  • Reversible flow with safety confirmation

BSetup & operationControls

  • Calibration mode (drawdown test)
  • Auto and manual prime
  • Rotor jog
  • Adjustable ramp times
  • Programmable RPM limit
  • Resettable and lifetime revolution and runtime counters

CAccess & recordsHMI

  • Multi-pump control from a single display
  • Password protection
  • Event log
  • Multi-language support

DInstallationOrientation

  • Pump head rotates 180°
  • Motor and controller rotate 90°
  • Display mounts on the pump or remotely (VESA 75 × 75)

Pre-launch: Gen 1 Rev A figures. Specifications may change before production.

05 · Operating modes

Operating-mode
questions.

What operating modes does the Keco Drive have?

Eight: Velocity, Duration, Volume, Flow Pacing, Analog Input, Frequency Input, Pulse and Calendar. Velocity, Duration and Volume are set locally on the touchscreen. Flow Pacing, Analog Input and Frequency Input follow an external signal. Pulse and Calendar trigger a set volume or run time from an input pulse or a schedule.

Can a PLC or SCADA system control the Keco Drive?

Yes. Hard-wired control uses an analog signal (4–20 mA, 0–20 mA or 0–10 V), a 0–1000 Hz frequency signal or input pulses. Network control uses PROFINET, EtherNet/IP or Modbus TCP.

What is the difference between Pulse and Calendar mode?

Both dose a set volume or run for a set time. Pulse mode starts the dose when the drive receives an input pulse from a digital or dry-contact signal. Calendar mode starts it on a schedule kept by the controller's real-time clock, which has battery backup.

How is flow calibrated?

With the built-in calibration mode, which is based on a drawdown test: you measure the pump's actual flow rate and enter it on the drive.

Which units can I program in?

Volume in milliliters, liters or gallons, and time in seconds, minutes, hours or days.

What happens if the hose fails?

The hose is the primary wear part of a peristaltic pump. The Keco Drive has a leak-detector input for hose failure and an auxiliary safety input, and it includes adaptive hose-life estimation with an alert.

Does the drive restart after a power interruption?

Yes. Auto restart after a power interruption is a built-in function, and the controller uses non-volatile memory.